Skip to main content
All CollectionsKnowledge BaseEnterprise WorkloadsTroubleshooting - Enterprise Workloads
Unable to ping or RDP to the EC2 instance after a DR failover
Unable to ping or RDP to the EC2 instance after a DR failover
Updated over 8 months ago

Problem description

After a DR failover, an EC2 instance is successfully created. However, pings or RDP to this instance fail. RDP to the source VM is successful. If you disable the firewall on the source VM and perform a DR failover, the ping and RDP to the EC2 instance work. The Windows firewall has rules for port 445, and 50000 enabled.

Cause

Due to internal network restrictions on the Windows Firewall, the ICMPv4 connection fails.

Resolution

Enable ICMPv4 and RDP inbound rules in the local group policy settings of the Windows Firewall in the VM. The settings are illustrated below.
โ€‹

Windows firewall rules.png
Did this answer your question?